Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(48): e2305227120, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-37983514

RESUMO

Disease surveillance systems provide early warnings of disease outbreaks before they become public health emergencies. However, pandemics containment would be challenging due to the complex immunity landscape created by multiple variants. Genomic surveillance is critical for detecting novel variants with diverse characteristics and importation/emergence times. Yet, a systematic study incorporating genomic monitoring, situation assessment, and intervention strategies is lacking in the literature. We formulate an integrated computational modeling framework to study a realistic course of action based on sequencing, analysis, and response. We study the effects of the second variant's importation time, its infectiousness advantage and, its cross-infection on the novel variant's detection time, and the resulting intervention scenarios to contain epidemics driven by two-variants dynamics. Our results illustrate the limitation in the intervention's effectiveness due to the variants' competing dynamics and provide the following insights: i) There is a set of importation times that yields the worst detection time for the second variant, which depends on the first variant's basic reproductive number; ii) When the second variant is imported relatively early with respect to the first variant, the cross-infection level does not impact the detection time of the second variant. We found that depending on the target metric, the best outcomes are attained under different interventions' regimes. Our results emphasize the importance of sustained enforcement of Non-Pharmaceutical Interventions on preventing epidemic resurgence due to importation/emergence of novel variants. We also discuss how our methods can be used to study when a novel variant emerges within a population.


Assuntos
COVID-19 , Pandemias , Humanos , Pandemias/prevenção & controle , Saúde Pública , Surtos de Doenças/prevenção & controle , Genômica
2.
J Cardiovasc Electrophysiol ; 33(12): 2467-2472, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36217995

RESUMO

INTRODUCTION: Recently, the wide-band dielectric mapping system Kodex-EPD was introduced. This study reports the first clinical experience using a novel system to guide pulmonary vein isolation (PVI) with radiofrequency (RF) ablation. METHODS AND RESULTS: The study included 20 consecutive patients undergoing de-novo PVI for symptomatic paroxysmal or persistent atrial fibrillation guided by Kodex-EPD. The primary efficacy endpoint was successful PVI. Secondary endpoints included procedural parameters and complications. In all 20 patients (mean age 68 ± 8 years, 12 male patients, paroxysmal fibrillation in 14/20 [70%] patients), PVI was successfully completed. One patient underwent additional cavo-tricuspid isthmus ablation for concomitant typical atrial flutter and one patient required additional ablation of a focal atrial tachycardia. A conventional three-dimensional image of the left atrium as well as the innovative endocardial panoramic view were used to guide catheter manipulation and ablation. Median procedure time was 115 [1st; 3rd quartile 93,75; 140] min and median total fluoroscopy time was 9.9 [9.7; 11.2] min, of which a median of 0.8 [0.6; 0.9] min was required to create left atrial maps. Complete left atrial imaging using Kodex-EPD was achieved within a median of 7.1 [5.7; 8.3] min. Median RF ablation time was 45.1 [34.6; 58.7] min. No major complications were observed. CONCLUSION: RF ablation PVI guided by Kodex-EPD seems safe and feasible. The system provides effective three-dimensional guidance for PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Resultado do Tratamento
3.
Dtsch Arztebl Int ; (Forthcoming)2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-34789364

RESUMO

BACKGROUND: Atrial fibrillation is the most common type of cardiac arrhythmia; the lifetime risk for a 55-year-old person to develop atrial fibrillation is 37%. In recent years, years there have been various distinct changes in the clinical management of AF. METHODS: This review is based on a selective search for literature on the treatment of AF and the prevention of thromboembolic complications. The updated guideline of the European Society of Cardiology (ESC) for the diagnosis and treatment of AF was also taken into consideration. RESULTS: The main components of AF management are the comprehensive treatment of risk factors and concomitant diseases, as well as the prevention of thromboembolic complications, usually with non-vitamin-K-dependent oral anticoagulants or vitamin K antagonists, according to individual risk stratification. Beyond this, either rate or rhythm control are viable treatment concepts. Symptomatic patients in whom reversible causes have been ruled out should be offered rhythm-control therapy early in their course. In patients with risk factors and/or heart failure, an early rhythm control strategy has been found to be beneficial. As antiarrhythmic drugs often prove to be ineffective over the long term, catheter ablation is now becoming increasingly important in AF management. CONCLUSION: The clinical management of atrial fibrillation consists of a multimodal approach with risk stratification, lifestyle modification, prevention of thromboembolism, and, if possible, early rhythm control therapy.

4.
Dtsch Med Wochenschr ; 146(15): 982-987, 2021 08.
Artigo em Alemão | MEDLINE | ID: mdl-34344034

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia. The European Society of Cardiology released a new version of the guideline to streamline AF-management and current studies highlight the importance of early treatment.Oral anticoagulation to prevent thromboembolic events remains essential in AF-management for patients at risk. NOAK therapy, if possible, is recommend as first line treatment. In general rhythm or rate control strategies are available. Symptomatic patients and patients with heart failure should be offered an early rhythm control. Catheter ablation is effective for rhythm control and and should be offered early in AF treatment additional to treatment of risk factors and comorbidities.


Assuntos
Fibrilação Atrial , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter , Humanos , Tromboembolia/tratamento farmacológico , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
5.
Proc Natl Acad Sci U S A ; 118(1)2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33443196

RESUMO

Barrier islands are ubiquitous coastal features that create low-energy environments where salt marshes, oyster reefs, and mangroves can develop and survive external stresses. Barrier systems also protect interior coastal communities from storm surges and wave-driven erosion. These functions depend on the existence of a slowly migrating, vertically stable barrier, a condition tied to the frequency of storm-driven overwashes and thus barrier elevation during the storm impact. The balance between erosional and accretional processes behind barrier dynamics is stochastic in nature and cannot be properly understood with traditional continuous models. Here we develop a master equation describing the stochastic dynamics of the probability density function (PDF) of barrier elevation at a point. The dynamics are controlled by two dimensionless numbers relating the average intensity and frequency of high-water events (HWEs) to the maximum dune height and dune formation time, which are in turn a function of the rate of sea level rise, sand availability, and stress of the plant ecosystem anchoring dune formation. Depending on the control parameters, the transient solution converges toward a high-elevation barrier, a low-elevation barrier, or a mixed, bimodal, state. We find the average after-storm recovery time-a relaxation time characterizing barrier's resiliency to storm impacts-changes rapidly with the control parameters, suggesting a tipping point in barrier response to external drivers. We finally derive explicit expressions for the overwash probability and average overwash frequency and transport rate characterizing the landward migration of barriers.

6.
J Am Heart Assoc ; 10(3): e017451, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33455428

RESUMO

Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with a deterioration of clinical status. Ablation of symptomatic AF is an established therapy, but in HCM, the characteristics of recurrent atrial arrhythmias and the long-term outcome are uncertain. Methods and Results Sixty-five patients with HCM (aged 64.5±9.9 years, 42 [64.6%] men) underwent AF ablation. The ablation strategy included pulmonary vein isolation in all patients and ablation of complex fractionated atrial electrograms or subsequent atrial tachycardias (AT) if appropriate. Paroxysmal, persistent AF, and a primary AT was present in 13 (20.0%), 51 (78.5%), and 1 (1.5%) patients, respectively. Twenty-five (38.4%) patients developed AT with a total number of 54 ATs. Stable AT was observed in 15 (23.1%) and unstable AT in 10 (15.3%) patients. The mechanism was characterized as a macroreentry in 37 (68.5%), as a localized reentry in 12 (22.2%), a focal mechanism in 1 (1.9%), and not classified in 4 (7.4%) ATs. After 1.9±1.2 ablation procedures and a follow-up of 48.1±32.5 months, freedom of AF/AT recurrences was demonstrated in 60.0% of patients. No recurrences occurred in 84.6% and 52.9% of patients with paroxysmal and persistent AF, respectively (P<0.01). Antiarrhythmic drug therapy was maintained in 24 (36.9%) patients. Conclusions AF ablation in patients with HCM is effective for long-term rhythm control, and especially patients with paroxysmal AF undergoing pulmonary vein isolation have a good clinical outcome. ATs after AF ablation are frequently observed in HCM. Freedom of atrial arrhythmia is achieved by persistent AF ablation in a reasonable number of patients even though the use of antiarrhythmic drug therapy remains high.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 30(5): 679-687, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30821012

RESUMO

INTRODUCTION: Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). METHODS AND RESULTS: A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. CONCLUSION: Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.


Assuntos
Arritmias Cardíacas/terapia , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Veias Pulmonares/cirurgia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Ablação por Cateter/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
8.
Proc Math Phys Eng Sci ; 474(2214): 20170649, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29977123

RESUMO

In arid or semi-arid ecosystems, water availability is one of the primary controls on vegetation growth. When subsurface water resources are unavailable, the vegetation growth is dictated by the rainfall, and the random nature of the rainfall arrivals and quantities induces a probability distribution of soil moisture and vegetation biomass via the coupled dynamic equations of biomass balance and water balance. We have previously obtained an exact solution for these distributions under certain conditions, and shown that the mapping of rainfall variability to observed biomass variability can be successfully applied to a field site. Here, we expand upon our earlier theoretical work to show how the dynamics can give rise to more complicated, bimodal (and multimodal) structures in the biomass distribution when positive feedbacks between growth and water availability are included. We also derive some new analytical results for the crossing properties of this system, which enable us to determine on what time scale the effects of these feedbacks will be felt, and, relatedly, how long the system will take to cross between different modes.

9.
Europace ; 20(3): 520-527, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340078

RESUMO

Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/cirurgia , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Seio Aórtico/cirurgia , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Fluoroscopia , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/fisiopatologia , Resultado do Tratamento , Função Ventricular Esquerda
10.
Proc Natl Acad Sci U S A ; 114(25): E4944-E4950, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28584097

RESUMO

The temporal dynamics of vegetation biomass are of key importance for evaluating the sustainability of arid and semiarid ecosystems. In these ecosystems, biomass and soil moisture are coupled stochastic variables externally driven, mainly, by the rainfall dynamics. Based on long-term field observations in northwestern (NW) China, we test a recently developed analytical scheme for the description of the leaf biomass dynamics undergoing seasonal cycles with different rainfall characteristics. The probabilistic characterization of such dynamics agrees remarkably well with the field measurements, providing a tool to forecast the changes to be expected in biomass for arid and semiarid ecosystems under climate change conditions. These changes will depend-for each season-on the forecasted rate of rainy days, mean depth of rain in a rainy day, and duration of the season. For the site in NW China, the current scenario of an increase of 10% in rate of rainy days, 10% in mean rain depth in a rainy day, and no change in the season duration leads to forecasted increases in mean leaf biomass near 25% in both seasons.


Assuntos
Desenvolvimento Vegetal/fisiologia , Folhas de Planta/crescimento & desenvolvimento , Biomassa , China , Mudança Climática , Clima Desértico , Ecossistema , Modelos Estatísticos , Chuva , Estações do Ano , Solo
11.
J Cardiovasc Electrophysiol ; 28(9): 1058-1067, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28597532

RESUMO

BACKGROUND: Ablation of scar-related ventricular tachycardia (VT), especially in noninducible VT or hemodynamically unstable patients, can be challenging. Thus, we evaluated feasibility of an ultra high-density 3-D mapping approach to characterize the ventricular substrate and, if possible, to map VT. METHODS AND RESULTS: Twenty-two patients (67 ± 2 years, mean LV-EF 36 ± 3%) with both ischemic and nonischemic cardiomyopathy and documented VT underwent mapping and catheter ablation using a 64-electrode mini-basket catheter. Substrate characterization included ultra high-density voltage maps, identification of areas of slow conduction and late potentials. Whenever VT was inducible activation mapping was performed. In 13 of 22 patients, the presumed clinical VT (in 16 of 22 any VT) was inducible. A total of 50 maps were generated (22 substrate maps, 28 during VT), mapping time was 33 ± 4 minutes, number of points was 10,937 ± 1,923. Low voltage areas were related with the site of origin in all mapped VT. Isochronal maps indicated areas of slow conduction in 14 of 22 patients, all in border zone scar. In 95% of patients, late potentials were found. Mapping time during VT was 9 ± 2 minutes, number of points 6,740 ± 1,140. Covered cycle length was 82 ± 5% (16 re-entry, 10 focal, and two undetermined). During 4 months follow-up, 90% remained free from VT recurrence. CONCLUSION: Ultra high-density mapping in patients with scar-related VT is feasible, safe and enables detailed insight into tachycardia mechanisms. Critical sites can be identified (1) by precise substrate characterization when VT is not inducible or hemodynamically not tolerated and (2) during short lasting episodes of VT in order to guide catheter ablation.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cardiomiopatias/complicações , Ablação por Cateter/métodos , Cicatriz/complicações , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Taquicardia Ventricular/cirurgia , Idoso , Cardiomiopatias/diagnóstico , Cicatriz/diagnóstico , Eletrocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Curva ROC , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do Tratamento
12.
IEEE Trans Biomed Eng ; 64(2): 310-318, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27101596

RESUMO

OBJECTIVE: To explore technical challenges of phase singularity (PS) mapping during atrial fibrillation (AF) using direct contact electrograms. METHODS: AF mapping was performed in high-density epicardial recordings of human paroxysmal (PAF) or persistent (PersAF) (N = 20 pts) AF with an array of 16 × 16 electrodes placed on atrial epicardium. PS points were detected using subsets of electrodes forming rings of varying sizes. RESULTS: PS detection using a 2 × 2 electrode ring identified 0.88 ± 1.00 PS/s in PAF group and 3.91 ± 2.51 per s in PersAF group (p < 0.001) in 2.4 × 2.4 cm mapping area. All detected PS had a short lifespan with the longest being 1100 ms (6.8 rotations). Exploration of the PS detection in a numerical model demonstrated that at least eight electrodes are required to avoid frequent false positive PS detection due to chance. Application of a detection grid consisting a double ring of electrodes (2 × 2 and 4 × 4 rings) decreased the number of false positive detections. The double ring was more resilient to electrode swapping (with just three instances of false positives versus 4380 false positives using 2 × 2 ring). CONCLUSIONS: The number of detected rotors critically depends upon the parameters of the detection algorithm, especially the number of electrodes used to detect PS. Based on our results, we recommend double ring comprised of 2 × 2 and 4 × 4 grid of electrodes for robust rotor detection. SIGNIFICANCE: Great methodological care has to be taken before equating detected PS with rotating waves and using PS detection algorithms to guide catheter ablation of AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Algoritmos , Humanos , Modelos Cardiovasculares
13.
JACC Clin Electrophysiol ; 3(11): 1262-1271, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29759622

RESUMO

OBJECTIVES: This study sought to compare long-term arrhythmia-free survival between electrical circumferential pulmonary vein isolation (PVI) and PVI with the endpoint of unexcitability along the ablation line. BACKGROUND: PVI is the standard ablation strategy of paroxysmal atrial fibrillation, although arrhythmia recurrence in long-term follow-up (FU) is high. The endpoint of unexcitability along the ablation line results in decreased arrhythmia recurrence compared to electrical PVI in 1-year FU. METHODS: Seventy-four consecutive patients (age 62.5 ± 10.6 years; 70.3% male) with de novo paroxysmal atrial fibrillation who were initially included in our randomized trial and underwent catheter ablation at our institution were analyzed. Patients who were randomized to either a conventional group (PVI, guided by circumferential catheter signals) or a pace-guided group (PG, anatomical ablation line encircling, ablation until loss of pace capture at 10 V, 2-ms pulse width on the ablation line) underwent long-term FU. The primary endpoint was recurrence of any atrial fibrillation or atrial tachycardia after a blanking period of 3 months. RESULTS: Sixty-nine patients completed a mean FU period of 5.14 ± 0.98 years. Arrhythmia-free survival without antiarrhythmic drug therapy was significantly higher in the PG group (71.05% vs. 25.81%, p = 0.002). Furthermore, multiple procedure success (1.29 ± 0.61 procedures in PG vs. 1.97 ± 1.06 procedures in conventional group, p < 0.001) was higher in the PG group compared to the conventional group (89.47% vs. 58.06%, p = 0.005). CONCLUSIONS: The endpoint of unexcitability along the PVI line improves success rates, resulting in a significant reduction of exposure to invasive procedures in 5-year FU.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Terapia por Estimulação Elétrica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiologia , Recidiva , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 40(2): 175-182, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27995637

RESUMO

BACKGROUND: Extensive and repeated substrate modification (SM) is frequently performed as an ablation strategy in persistent atrial fibrillation (persAF). The effect of these extended ablation strategies on atrial function has not been investigated sufficiently so far. The purpose was to assess atrial function by cardiac magnetic resonance (CMR) and its association with left atrial (LA) scar burden by electroanatomical voltage-mapping after multiple persAF ablation procedures. METHODS: We included 16 persAF patients who had ≥2 SM procedures and a control group (CG) of 21 persAF patients without prior ablation. CMR was performed in sinus rhythm at least 4 weeks after the last cardioversion. Active left and right (RA) atrial emptying fractions (AEF) as well as peak active left atrial appendage (LAA) emptying velocities were obtained by CMR flow measurements. Furthermore, LA scar burden was quantified on electroanatomical voltage maps by the portion of points with local voltage amplitude <0.2 mV. RESULTS: We found median LA-AEF to be lower (13 [9-22] vs 32 [26-36] %, P < 0.001) and median LA scar burden to be higher (40 [20-68] vs nine [3-18] %, P < 0.05) in the SM group compared with the CG. Furthermore, a significant correlation was found between mean LA voltage and LA-AEF (r2 = 0.62, P < 0.001). No significant differences were detected with respect to median RA-AEF (41 [28-48] vs 47 [35-50] %, P = 0.43) and median peak LAA emptying velocities (30 [16-40] vs 17 [13-28] cm/s, P = 0.07). CONCLUSIONS: Active LA function is preserved but significantly impaired and associated with ablation-related LA scar burden after multiple extensive persAF ablations.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função Atrial , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Cicatriz/etiologia , Idoso , Fibrilação Atrial/diagnóstico , Doença Crônica , Cicatriz/patologia , Cicatriz/fisiopatologia , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reoperação/efeitos adversos , Resultado do Tratamento
15.
PLoS One ; 11(10): e0164236, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27780243

RESUMO

BACKGROUND: Electrogram-based identification of the regions maintaining persistent Atrial Fibrillation (AF) is a subject of ongoing debate. Here, we explore the concept of local electrical dyssynchrony to identify AF drivers. METHODS AND RESULTS: Local electrical dyssynchrony was calculated using mean phase coherence. High-density epicardial mapping along with mathematical model were used to explore the link between local dyssynchrony and properties of wave conduction. High-density mapping showed a positive correlation between the dyssynchrony and number of fibrillatory waves (R2 = 0.68, p<0.001). In the mathematical model, virtual ablation at high dyssynchrony regions resulted in conduction regularization. The clinical study consisted of eighteen patients undergoing catheter ablation of persistent AF. High-density maps of left atrial (LA) were constructed using a circular mapping catheter. After pulmonary vein isolation, regions with the top 10% of the highest dyssynchrony in LA were targeted during ablation and followed with ablation of complex atrial electrograms. Catheter ablation resulted in termination during ablation at high dyssynchrony regions in 7 (41%) patients. In another 4 (24%) patients, transient organization was observed. In 6 (35%) there was no clear effect. Long-term follow-up showed 65% AF freedom at 1 year and 22% at 2 years. CONCLUSIONS: Local electrical dyssynchrony provides a reasonable estimator of regional AF complexity defined as the number of fibrillatory waves. Additionally, it points to regions of dynamical instability related with action potential alternans. However, despite those characteristics, its utility in guiding catheter ablation of AF is limited suggesting other factors are responsible for AF persistence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Mapeamento Epicárdico/métodos , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Terapia Combinada , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Projetos Piloto , Resultado do Tratamento
16.
Physiol Rep ; 4(17)2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27613823

RESUMO

Hypertension is a major risk factor for many cardiovascular diseases and leads to subsequent concomitant pathologies such as left ventricular hypertrophy (LVH). Translational approaches using large animals get more important as they allow the use of standard clinical procedures in an experimental setting. Therefore, the aim of this study was to establish a minimally invasive ovine hypertension model using chronic angiotensin II (ANG II) treatment and to characterize its effects on cardiac remodeling after 8 weeks. Sheep were implanted with osmotic minipumps filled with either vehicle control (n = 7) or ANG II (n = 9) for 8 weeks. Mean arterial blood pressure in the ANG II-treated group increased from 87.4 ± 5.3 to 111.8 ± 6.9 mmHg (P = 0.00013). Cardiovascular magnetic resonance imaging showed an increase in left ventricular mass from 112 ± 12.6 g to 131 ± 18.7 g after 7 weeks (P = 0.0017). This was confirmed by postmortem measurement of left ventricular wall thickness which was higher in ANG II-treated animals compared to the control group (18 ± 4 mm vs. 13 ± 2 mm, respectively, P = 0.002). However, ANG II-treated sheep did not reveal any signs of fibrosis or inflammatory infiltrates as defined by picrosirius red and H&E staining on myocardial full thickness paraffin sections of both atria and ventricles. Measurements of plasma high-sensitivity C-reactive protein and urinary 8-iso-prostaglandin F2α were inconspicuous in all animals. Furthermore, multielectrode surface mapping of the heart did not show any differences in epicardial conduction velocity and heterogeneity. These data demonstrate that chronic ANG II treatment using osmotic minipumps presents a reliable, minimally invasive approach to establish hypertension and nonfibrotic LVH in sheep.


Assuntos
Angiotensina II/efeitos adversos , Ventrículos do Coração/efeitos dos fármacos , Coração/efeitos dos fármacos , Hipertensão/induzido quimicamente , Hipertrofia Ventricular Esquerda/induzido quimicamente , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Vasoconstritores/efeitos adversos , Angiotensina II/metabolismo , Animais , Autopsia , Fibrose , Coração/diagnóstico por imagem , Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/patologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Modelos Animais , Fatores de Risco , Ovinos , Vasoconstritores/metabolismo , Remodelação Ventricular
17.
Europace ; 18(8): 1245-51, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27247017

RESUMO

AIMS: Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS: Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION: Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.


Assuntos
Ablação por Cateter/métodos , Hipnóticos e Sedativos/administração & dosagem , Midazolam/uso terapêutico , Propofol/administração & dosagem , Taquicardia Ventricular/terapia , Idoso , Pressão Sanguínea/efeitos dos fármacos , Cardiologistas , Desfibriladores Implantáveis , Feminino , Alemanha , Humanos , Hipotensão/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Europace ; 18(7): 994-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26462703

RESUMO

AIMS: Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS: Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION: In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Taquicardia/epidemiologia , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica , Eletrocardiografia , Feminino , Alemanha , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
19.
J Am Coll Cardiol ; 66(24): 2743-2752, 2015 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-26700836

RESUMO

BACKGROUND: Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES: This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS: From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS: During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS: A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
20.
J Cardiovasc Electrophysiol ; 26(7): 747-53, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25807878

RESUMO

INTRODUCTION: Recently, a new image integration module (IIM, CartoUnivu™ Module) has been introduced to combine and merge fluoroscopy images with 3-dimensional-(3D)-electroanatomical maps (Carto® 3 System) into an accurate 3D view. The aim of the study was to investigate the influence of IIM on the fluoroscopy exposure during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS AND RESULTS: Between June and November 2014, a total of 60 patients with PAF (73.3% male, 64.0 ± 9.2 years), who underwent PVI with the endpoint of unexcitability of the ablation line, were randomized to either a conventional 3D mapping system (Carto® 3 System) or to an additional IIM on the basis of an assumed reduction of fluoroscopy exposure by the use of IIM. There were no significant differences in baseline characteristics. The median ablation procedure time was identical in both groups (140.7 ± 27.8 minutes vs. 140.8 ± 39.5 minutes; P = 0.851). A significant decrease of mean fluoroscopy time from 11.9 ± 2.1 to 7.4 ± 2.6 minutes (P < 0.0006) and median fluoroscopy dose from 882.9 to 476.5 cGycm(2) (P < 0.001) was achieved. The main reduction of radiation could be realized during creation of the 3D-map. No major complications occurred during the procedures. After a median follow-up of 125.7 ± 45.6 days 80% of the patients were free from any atrial arrhythmias. CONCLUSION: CartoUnivu™ module easily integrates into the workflow of PVI with the endpoint of unexcitability of the ablation line without prolonging the procedure time. It is associated with a marked reduction in fluoroscopic dose when compared to a conventional 3D mapping system.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Intervencionista/métodos , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Viabilidade , Feminino , Fluoroscopia , Alemanha , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...